Brocade Communications Systems StoreFabric SN6500B Reference page 610

Brocade fabric os message reference v7.1.0 (53-1002749-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

5
KTRC-1001
KTRC Messages
KTRC-1001
Message
Dump memory size exceeds dump file size.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the dump memory size has exceeded the dump file size.
Recommended
Execute the supportSave command and reload the switch. If the problem persists, contact your switch
Action
service provider.
KTRC-1002
Message
Concurrent trace dumping.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the initial background dump has not completed.
Recommended
No action is required.
Action
KTRC-1003
Message
Cannot open ATA dump device.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the advanced technology attachment (ATA) dump driver is not initialized properly.
Recommended
Execute the supportSave command and reload the switch. If the problem persists, contact your switch
Action
service provider.