Brocade Communications Systems StoreFabric SN6500B Reference page 344

Brocade fabric os message reference v7.1.0 (53-1002749-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

5
FABS-1005
FABS-1005
Message
<Function name and description of problem> (<ID type>= <ID number>).
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that an unsupported operation has been requested. This is usually an internal Fabric OS
problem or file corruption. The following is a possible value for function name and description of problem
variable:
fabsys_write: Unsupported write operation: process xxx
In this value, xxx is the process ID (PID), which could be any whole number.
Recommended
Reboot or power cycle the active CP (for modular systems) or the switch (for single-board systems).
Action
If the message persists, run the firmwareDownload command to update the firmware.
FABS-1006
Message
<Function name and description of problem>: object <object type id> unit <slot>.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that there is no device in the slot with the specified object type ID in the system module record.
This could indicate a serious Fabric OS data problem on the switch. The possible values for function
name and description of problem variable are:
Recommended
If the message is isolated, monitor the error messages on the switch. If the error is repetitive or if the
Action
fabric failed, failover or reboot the switch.
If the message persists, run the firmwareDownload command to update the firmware.
322
setSoftState: bad object
setSoftState: invalid type or unit
media_sync: Media oid mapping failed
fabsys_media_i2c_op: Media oid mapping failed
fabsys_media_i2c_op: obj is not media type
media_class_hndlr: failed sending media state to blade driver