Brocade Communications Systems StoreFabric SN6500B Reference page 278

Brocade fabric os message reference v7.1.0 (53-1002749-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

5
CVLC-1034
CVLC-1034
Message
Rekey failed on Container: <Target container name>, Initiator: <Initiator physical
WWN>, LUN ID: <LUN ID> because <Failure reason>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the first-time encryption, key expired, or manual re-key operation failed.
Recommended
No action is required.
Action
CVLC-1035
Message
A decommissioned LUN has been added back as encrypted LUN. Container: <Target
container name>, Initiator: <Initiator physical WWN>, LUN ID: <LUN ID>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that a decommissioned LUN has been added as an encrypted LUN.
Recommended
Perform the following steps.
Action
1. Remove the LUN from the container.
2. Add the LUN back as a cleartext LUN.
3. Modify the LUN policy to encrypt.
CVLC-1039
Message
Refresh DEK operation <Refresh DEK status (SUCCEEDED/FAILED)>. Container: <Target
container name>, Initiator: <Initiator physical WWN>, LUN ID: <LUN ID>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates the status of the refresh DEK operation.
Recommended
No action is required.
Action