Brocade Communications Systems StoreFabric SN6500B Reference page 191

Brocade fabric os message reference v7.1.0 (53-1002749-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

BL-1016
Message
Blade port <port number> in slot <slot number> failed to enable.
Message Type
FFDC | LOG
Severity
CRITICAL
Probable Cause
Indicates that the specified blade port could not be enabled.
Recommended
Make sure that the blade is seated correctly.
Action
If the blade is seated correctly, execute the diagPost command to make sure that Power-On Self-Test
(POST) is enabled; then power cycle the blade using the slotPowerOff and slotPowerOn commands or
have the blade's ejector switch cycled to run POST and verify that the blade does not have any hardware
problems.
If the message persists, replace the blade.
BL-1017
Message
Slot <slot number> Initializing...
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the slot has started initializing the ports.
Recommended
No action is required.
Action
BL-1018
Message
Slot <slot number> Initialization completed.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the slot has completed initializing the ports.
Recommended
No action is required.
Action
Fabric OS Message Reference
53-1002749-01
5
BL-1016
169

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric os v7.1.0

Table of Contents