5
BL-1025
BL-1025
Message
All GigE/FCIP/Virtualization/FC Fastwrite ports on the blade in slot <slot number>
will be reset as part of the firmware upgrade.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that a recent firmware upgrade caused the blade's firmware to be upgraded and resulted in the
cold upgrade. As part of the upgrade, all the Gigabit Ethernet, Fibre Channel over IP (FCIP),
virtualization data elements, and FC Fastwrite ports were reset.
Recommended
No action is required.
Action
BL-1026
Message
Internal port offline during warm recovery, state <port state> (0x<port ID>).
Message Type
LOG
Severity
CRITICAL
Probable Cause
Indicates that an internal port went offline during warm recovery of the switch. The switch will reboot and
start cold recovery.
Recommended
Execute the supportSave command and then reboot switch. If the problem persists, replace the switch.
Action
BL-1027
Message
Blade in slot <slot number> faulted, boot failed; status 0x<boot status> 0x<1250 0
boot status> 0x<1250 1 boot status>.
Message Type
LOG
Severity
CRITICAL
Probable Cause
Indicates that the blade failed to boot properly.
Recommended
Reboot or power cycle the blade using the slotPowerOff and slotPowerOn commands.
Action
If the message persists, replace the blade.