Brocade Communications Systems StoreFabric SN6500B Reference page 439

Brocade fabric os message reference v7.1.0 (53-1002749-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

FICN-2085
Message
FICON or FCP Emulation Enabled FCIP Tunnel is Up on VEPort=<VEPortNumber>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates a FICON or Fibre Channel Protocol (FCP) emulation-enabled FCIP tunnel has been
established successfully to the peer switch.
Recommended
No action is required.
Action
FICN-2086
Message
FICON or FCP Emulation Enabled FCIP Tunnel is Down on VEport=<VEPortNumber>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates a FICON or Fibre Channel Protocol (FCP) emulation-enabled FCIP tunnel to the peer switch
has been terminated.
Recommended
This is an unexpected event; contact your vendor's customer support for assistance.
Action
FICN-2087
Message
FICON connected 3900 printer discovered Path=0x<VEPortNumber HostDomain HostPort
DeviceDomain><DevicePort LPAR CUADDR DeviceAddr>-invalid compression mode.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that FICON Printer emulation is enabled, but cannot be performed for this device because the
compression mode on the tunnel is not set to None or Aggressive.
Recommended
If you desire FICON Printer emulation for this device, modify the tunnel compression mode to None
Action
(mode 0) or Aggressive (mode 3).
Fabric OS Message Reference
53-1002749-01
5