CDR-1014
Message
Link Reset on Internal Port S<slot number>,P<port number>(<blade port number>)
vc_no=<vc number> crd(s)lost=<Credit(s) lost>.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that one or more credits were lost and the link is reset.
Recommended
When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
Action
slotPowerOn commands. If the problem persists, replace the blade.
CDR-1015
Message
Port re-initialized due to Link Reset failure on internal Port S<slot
number>,P<port number>(<blade port number>).
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that specified port got re-initialized due to link reset failure.
Recommended
When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
Action
slotPowerOn commands. If the problem persists, replace the blade.
CDR-1016
Message
Port is faulted due to port re-initialization failure on internal Port S<slot
number>,P<port number>(<blade port number>) with reason <port fault reason>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the specified port is faulted due to port re-initialization failure.
Recommended
When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
Action
slotPowerOn commands. If the problem persists, replace the blade.
Fabric OS Message Reference
53-1002749-01
5