The SNMP traps are unreliable because the trap recipient does not send any acknowledgment
when it receives a trap. Therefore, the SNMP agent cannot determine if the trap was received.
Brocade switches send traps out on UDP port 162. To receive traps, the management station IP
address must be configured on the switch. You can configure the SNMPv1 and SNMPv3 hosts to
receive the traps.
For more information on the swEventTrap, refer to the Fabric OS MIB Reference.
Configuring the SNMPv1 trap recipient
Use the snmpConfig
configure the SNMPv1 host to receive the trap, perform the following steps.
1. Log in to the switch as admin.
2. Execute the snmpConfig
3. Execute the snmpConfig
Fabric OS Message Reference
53-1002749-01
set snmpv1 command to specify the recipient of the SNMP trap. To
--
switch:admin> snmpconfig --set snmpv1
SNMP community and trap recipient configuration:
Community (rw): [Secret C0de]
Trap Recipient's IP address : [192.0.2.2]
Trap recipient Severity level : (0..5) [4]
Trap recipient Port : (0..65535) [162]
Community (rw): [OrigEquipMfr]
Trap Recipient's IP address : [fec0:60:22bc:200:313:72ff:fe64:78b2]
NOTE
To receive the traps, the management station IP address must be configured on the switch.
--
switch:admin> snmpconfig --show snmpv1
SNMPv1 community and trap recipient configuration:
Community 1: Secret C0de (rw)
Trap recipient: 192.0.2.2
Trap port: 162
Trap recipient Severity level: 5
Community 2: OrigEquipMfr (rw)
Trap recipient: fec0:60:22bc:200:313:72ff:fe64:78b2
Trap port: 162
Trap recipient Severity level: 5
Community 3: private (rw)
Trap recipient: tools.lab.brocade.com
Trap port: 162
Trap recipient Severity level: 5
Community 4: public (ro)
Trap recipient: 192.0.10.10
Trap port: 65530
Trap recipient Severity level: 1
Community 5: common (ro)
Trap recipient: fec0:60:69bc:200:213:72ff:fe64:069f
Trap port: 11
Trap recipient Severity level: 2
Community 6: FibreChannel (ro)
Trap recipient: WT.org.brocade.com
Trap port: 65521
Configuring the syslog message destinations
set snmpv1 command to configure the SNMP trap recipient.
--