HIL-1101
HIL Messages
HIL-1101
Message
Slot <slot number> faulted, <nominal voltage> (<measured voltage>) is above
threshold.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the blade voltage is above threshold.
Recommended
Replace the faulty blade or switch (for non-bladed switches).
Action
HIL-1102
Message
Slot <slot number> faulted, <nominal voltage> (<measured voltage>) is below
threshold.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the blade voltage is below threshold.
Recommended
Replace the faulty blade or switch (for non-bladed switches).
Action
HIL-1103
Message
Blower <blower number> faulted, <nominal voltage> (<measured voltage>) is above
threshold.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the fan voltage is above threshold.
Recommended
Run the psShow command to verify the power supply status.
Action
Try to reseat the faulty fan field-replaceable units (FRUs) and power supply FRU to verify that they are
seated properly.
If the problem persists, replace the fan FRU or the power supply FRU as necessary.