Brocade Communications Systems StoreFabric SN6500B Reference page 592

Brocade fabric os message reference v7.1.0 (53-1002749-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

5
HSL-1006
HSL-1006
Message
Failed to get kernel page size <PageSize> bytes for mmap.
Message Type
LOG
Severity
CRITICAL
Probable Cause
Indicates that there is not enough contiguous kernel memory.
Recommended
Install more memory on the board.
Action
HSL-1007
Message
Failed to read SFP for interface <InterfaceName>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates failure to read the small form-factor pluggable (SFP) transceiver on the specified interface.
Recommended
Disable the interface using the shutdown command and re-insert the SFP transceiver. After the SFP
Action
transceiver is inserted, re-enable the interface using the no shutdown command. If the problem persists,
contact your switch service provider.