SEC-1049
Message
Invalid switch name <switch name>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates a corruption occurred during the distribution of the security database. This can only occur when
the primary fabric configuration server (FCS) distributes the security database to the other switches in
the fabric, and then local validation finds the error in the security database. This is a rare occurrence.
Recommended
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in
Action
the ready state. If a switch is in the error state, the database may not be correctly updated for that
specific switch.
SEC-1050
Message
There are more than one switches with the same name <switch name> in the fabric.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates a corruption occurred during the distribution of the security database. This can only occur when
the primary fabric configuration server (FCS) distributes the security database to the other switches in
the fabric, and then local validation finds the error in the security database. This is a rare occurrence.
Recommended
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in
Action
the ready state. If a switch is in the error state, the database may not be correctly updated for that
specific switch.
SEC-1051
Message
Missing brace for port list <port list>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates a corruption occurred during the distribution of the security database. This can only occur when
the primary fabric configuration server (FCS) distributes the security database to the other switches in
the fabric, and then local validation finds the error in the security database. This is a rare occurrence.
Recommended
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in
Action
the ready state. If a switch is in the error state, the database may not be correctly updated for that
specific switch.
Fabric OS Message Reference
53-1002749-01
5
SEC-1049