5
CVLM-1001
CVLM Messages
CVLM-1001
Message
Failed to allocate memory: (<function name>).
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the specified function has failed to allocate memory.
Recommended
Check the memory usage on the switch using the memShow command.
Action
Restart or power cycle the switch.
CVLM-1002
Message
Failed to initialize <module> rc = <error>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the initialization of a module within the Crypto Virtual LUN Manager (CVLM) daemon has
failed.
Recommended
Download a new firmware version using the firmwareDownload command.
Action
CVLM-1003
Message
Crypto device configuration has been committed by switch (<Switch WWN>).
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the specified switch has committed a crypto device configuration.
Recommended
No action is required.
Action