Verify the security event was planned. If the security event was planned, no action is required. If the
Action
security event was not planned, take appropriate action as defined by your enterprise security policy.
SEC-1135
Message
Secure fabric version stamp has been reset.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates the version stamp of the secure fabric is reset.
Recommended
Verify the security event was planned. If the security event was planned, no action is required. If the
Action
security event was not planned, take appropriate action as defined by your enterprise security policy.
SEC-1136
Message
Failed to verify signature <data type, MUA, policy, etc.,>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates the receiving switch failed to validate the security database sent from the primary fabric
configuration server (FCS) switch. This message usually indicates that the data package is corrupted,
the time stamp on the package is out of range as a result of a replay attack or out-of-sync time service, or
the signature verification failed. Signature verification failure indicates either an internal error (such as
losing the primary public key) or an invalid database.
Recommended
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in
Action
the ready state. If a switch is in the error state, the database may not be correctly updated for that switch.
This message may also be the result of an internal corruption or a hacker attack to the secure fabric.
SEC-1137
Message
No signature in <data type, MUA, policy, etc.,>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates the receiving switch failed to validate the security database sent from the primary fabric
configuration server (FCS) switch. This message usually indicates that the data package is corrupted,
the time stamp on the package is out of range as a result of a replay attack or out-of-sync time service, or
the signature verification failed. Signature verification failure indicates either an internal error (such as
losing the primary public key) or an invalid database.
Recommended
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in
Action
the ready state. If a switch is in the error state, the database may not be correctly updated for that switch.
This message may also be the result of an internal corruption or a hacker attack to the secure fabric.
Fabric OS Message Reference
53-1002749-01
5
SEC-1135
721

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric os v7.1.0

Table of Contents