5
SSMD-1001
SSMD Messages
SSMD-1001
Message
Failed to allocate memory: (<function name>).
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the specified function has failed to allocate memory.
Recommended
Check the memory usage on the switch using the memShow command.
Action
Restart or power cycle the switch.
SSMD-1002
Message
Failed to initialize <module> rc = <error>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the initialization of a module within System Services Manager (SSM) has failed.
Recommended
Download a new firmware using the firmwareDownload command.
Action
SSMD-1003
Message
Failed to lock semaphore mutex: (<function name>).
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the specified function has failed to lock the mutex (semaphore).
Recommended
Restart or power cycle the switch.
Action
810