5
CVLM-1014
CVLM-1014
Message
RD zone getting deleted for which there is no Host/Target
(<HostPortWWN>/<TargetPortWWN>) L2 zone exists in effective configuration.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates deletion of Frame Redirect (RD) zone and there is no corresponding Layer 2 zone present, but
IT pair is in crypto configuration.
Recommended
Disable the target access to the host, recreate the Layer 2 zone for host and target, and run the
Action
cryptocfg --commit command again to recreate the RD zone.
CVLM-1015
Message
Unable to read basewwn from blade in slot <Slot>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates a failure to read the base WWN programmed on SEEPROM from this blade. Probably,
SEEPROM is not programmed properly.
Recommended
WWN allocation is not possible from this blade, but the blade can be used for crypto operations.
Action
SEEPROM needs to be reprogrammed on this blade.
CVLM-1016
Message
Invalid base WWN (<BaseWWN>) and/or page index (<Page>) received from the blade in
slot <Slot>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that invalid base WWN and index are read from SEEPROM on this blade. Probably,
SEEPROM is not programmed properly.
Recommended
WWN allocation is not possible from this blade, but the blade can be used for crypto operations.
Action
SEEPROM needs to be reprogrammed on this blade.