5
FBC-1001
FBC Messages
FBC-1001
Message
Firmware version on AP blade is incompatible with that on the CP.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates the control processor (CP) blade determined that the firmware version running on the
application processor (AP) blade is not compatible with that running on CP. The AP and CP blades
cannot communicate.
Recommended
The problem can be corrected by changing the firmware version on either the CP or on the AP blade.
Action
You can modify the firmware version on the CP blade by using the firmwareDownload command. Refer
to the release notes to determine whether a non-disruptive firmware download is supported between the
revisions. Because the AP and CP blades cannot communicate, it is not possible to load new firmware
on the AP blade. If necessary, send the AP blade back to the factory for a firmware update.