5
FCOE-1009
Recommended
Check the IfIndex limit displayed in the message.
Action
FCOE-1009
Message
Addition of N_Port mapping failed. Max N_Port mapping limit reached: <max n_port>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the N_Port mapping has reached its maximum limit.
Recommended
Remove unwanted N_Port mappings using the fcoelogingroup --remove command and try adding
Action
N_Port mapping using the fcoelogingroup --add command.
FCOE-1010
Message
FSS Registration or FCoE Trace initialization failed.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the Fabric OS state synchronization (FSS) registration or initialization of the FCoE trace
has failed.
Recommended
Execute the supportSave command and restart the system. If the problem persists, contact your switch
Action
service provider.
FCOE-1012
Message
Request to delete port from VLAN <vid> failed.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that a request to delete ports from the specified VLAN has failed.
Recommended
Execute the supportSave command and restart the system. If the problem persists, contact your switch
service provider.
Action