5
PORT-1005
PORT-1005
Message
Slot <slot number> port <port on slot> does not support configured L_Port. Issue
portCfgLport to clear configuration.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates the specified port is configured to be an L_Port, but the port does not support L_Port. If an
L_Port is connected, then the port will be disabled because the port does not support L_Port. If an
E_Port or F_Port is connected, then the port will not come up because it is configured to be an L_Port.
Recommended
Execute the portCfgLport command to clear the L_Port configuration.
Action
PORT-1006
Message
Configuration changed for port (ID: <port number>) in No_Module or No_Light state.
Message Type
AUDIT | LOG
Class
CFG
Severity
INFO
Probable Cause
Indicates the configuration changes were made to an offline port in the No_Module or No_Light state.
Recommended
No action is required.
Action
PORT-1007
Message
Port (ID: <port number>) has been renamed to (<port name>).
Message Type
AUDIT | LOG
Class
CFG
Severity
INFO
Probable Cause
Indicates a port has been reconfigured with a different name.
Recommended
No action is required.
Action