5
FLOD-1001
FLOD Messages
FLOD-1001
Message
Unknown LSR type: port <port number>, type <LSR header type>.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the link state record (LSR) type is unknown. The following two LSR header types are the
only known types:
Recommended
No action is required; the record is discarded.
Action
FLOD-1003
Message
Link count exceeded in received LSR, value = <link count number>.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the acceptable link count received was exceeded in the link state record (LSR).
Recommended
No action is required; the record is discarded.
Action
FLOD-1004
Message
Excessive LSU length = <LSU length>.
Message Type
LOG | FFDC
Severity
ERROR
Probable Cause
Indicates that the link state update (LSU) size exceeds the value the system can support.
Recommended
Reduce the number of switches in the fabric or reduce the number of redundant inter-switch links (ISLs)
Action
between two switches.