TRCE-1010
Message
Traced fails to start.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the trace daemon (traced), which is used for transferring trace files has failed to start. The
trace capability within the switch is unaffected. The system automatically restarts the traced facility after a
brief delay.
Recommended
Reboot the CP (dual-CP system) or restart the switch.
Action
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
TRCE-1011
Message
Trace dump manually transferred to target ' <optional string to indicate which
slot the trace dump is transferred> ': <result>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the trace dump files were manually transferred to the specified slot.
Recommended
No action is required.
Action
TRCE-1012
Message
The system was unable to retrieve trace information from slot <Slot number of the
blade on which the attempt was made>.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the system was unable to retrieve trace information from the specified slot because there is
no communication between the main system and the specified slot.
Recommended
Make sure the blade is enabled and retry the command. If the blade is already enabled, execute the
Action
supportSave command and contact your switch service provider.