5
C2-1019
C2-1019
Message
S<slot number>,C<chip index>: HW ASIC Chip TXQ FID parity error threshold reached
type = 0x<chip error type>.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that an internal error is observed in the application-specific integrated circuit (ASIC) hardware
that may degrade the data traffic.
Recommended
Restart the system at the next maintenance window.
Action
C2-1025
Message
S<slot number>,P<port number>(<blade port number>): Extra credit on
F_port:ftx=<ftx> curr_cred=<current credits> actual_cred=<actual credits>.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the device is returning the wrong number of receiver-ready (R_RDY) frames.
Recommended
When this error is observed persistently, replace the device.
Action
C2-1026
Message
S<slot number>,P<port number>(<blade port number>): Faulting F_port due to extra
credit detected:ftx=<ftx> curr_cred=<current credits> actual_cred=<actual
credits>.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the device is returning the wrong number of receiver-ready (R_RDY) frames.
Recommended
When this error is observed persistently, replace the device.
Action