Check the connection port for a possible security attack.
Action
Check the shared secrets using the secAuthSecret command and reinitialize authentication using the
portDisable and portEnable commands.
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
AUTH-3007
Message
Event: <Event Name>, Status: failed, Info: Port <port number> disabled due to
receiving an authentication reject with code '<Reason String>' and Explanation
'<Explanation String>'.
Message Type
AUDIT
Class
SECURITY
Severity
INFO
Probable Cause
Indicates that the specified port was disabled because it received an authentication-reject response from
the connected switch or device.
The error may indicate that an invalid entity tried to connect to the switch.
Recommended
Check the connection port for a possible security attack.
Action
Check the shared secrets using the secAuthSecret command and reinitialize authentication using the
portDisable and portEnable commands.
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
AUTH-3008
Message
Event: <Event Name>, Status: failed, Info: Port <port number> has been disabled
due to authentication failure with code '<Reason String>' and explanation
'<Explanation String>'.
Message Type
AUDIT
Class
SECURITY
Severity
INFO
Probable Cause
Indicates that the specified port has been disabled because the connecting switch or device failed to
authenticate.
The error may indicate that an invalid entity tried to connect to the switch.
Recommended
Check the connection port for a possible security attack.
Action
Check the shared secrets using the secAuthSecret command and reinitialize authentication using the
portDisable and portEnable commands.
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
Fabric OS Message Reference
53-1002749-01
5
AUTH-3007
161

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric os v7.1.0

Table of Contents