CVLC-1025
Message
Secondary Metadata exists for encrypted LUN not configured with -newLUN option.
Container: <Target container name>, Initiator: <Initiator physical WWN>, LUN ID:
<LUN ID>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the secondary metadata exists on the LUN that is not configured with the -newLUN option.
Recommended
Use the cryptoCfg command to remove and add the LUN with the -newLUN option.
Action
CVLC-1026
Message
Some secondary metadata missing for encrypted LUN configured with -newLUN option.
Container: <Target container name>, Initiator: <Initiator physical WWN>, LUN ID:
<LUN ID>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the secondary metadata does not exist on all logical block addresses (LBAs) for a LUN that
is configured with the -newLUN option.
Recommended
No action is required.
Action
CVLC-1027
Message
Encrypted LUN configured with -newLUN option does not contain any metadata.
Container: <Target container name>, Initiator: <Initiator physical WWN>, LUN ID:
<LUN ID>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the metadata was corrupted.
Recommended
No action is required.
Action