BM-1010
Message
Resetting port configuration and linkcost for all ports for blade in slot <Slot
number>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates the specified blade was detected for the first time after an FC10-6 was previously configured in
the same slot. The new blade requires resetting the port configuration and linkcost.
Recommended
No action is required. The blade ports are cleared automatically.
Action
BM-1053
Message
Failed to establish connection between CP and Application Processor. Faulting
switch.
Message Type
LOG | FFDC
Severity
WARNING
Probable Cause
Indicates that the control processor (CP) could not establish a connection with the application processor
(AP) to communicate.
Recommended
Execute the slotPowerOff and slotPowerOn commands or reseat the affected blade.
Action
BM-1054
Message
AP firmware <Blade firmware> is not consistent with system firmware <System
firmware>. Auto-leveling AP firmware to match system firmware.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the policy of the specified blade is set to auto-level the blade firmware to the system
firmware. This may be due to one of the following reasons:
Recommended
No action is required. The blade will automatically download the updated firmware.
Action
Fabric OS Message Reference
53-1002749-01
Blade firmware was detected to be different from the control processor (CP) firmware due to a
firmware upgrade.
The blade was recently inserted and had a different version of the firmware loaded.