Brocade Communications Systems StoreFabric SN6500B Reference page 655

Brocade fabric os message reference v7.1.0 (53-1002749-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

NSM Messages
NSM-1001
Message
Interface <InterfaceName> is online.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the specified interface has come online after the protocol dependencies are resolved.
Recommended
No action is required.
Action
NSM-1002
Message
Interface <InterfaceName> is protocol down.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the specified interface has gone offline because one of the protocol dependencies is
unresolved.
Recommended
Check for the reason codes using the show interface command and resolve the protocol dependencies.
Action
The following are the possible reason codes:
Fabric OS Message Reference
53-1002749-01
Admin down
Link protocol down
DOT1x authenticating
Minimum member links not UP (applicable only for port-channel interfaces)
DOT1x authentication failed
BRCD remote link negotiation failed/LLDP disabled
LAG negotiating/failed
LAG admin state is down
UNKNOWN
5
NSM-1001
633

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric os v7.1.0

Table of Contents