Brocade Communications Systems StoreFabric SN6500B Reference page 673

Brocade fabric os message reference v7.1.0 (53-1002749-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

PLAT Messages
PLAT-1000
Message
<Function name> <Error string>.
Message Type
FFDC | LOG
Severity
CRITICAL
Probable Cause
Indicates that nonrecoverable peripheral component interconnect (PCI) errors have been detected.
Recommended
The system will be faulted and may automatically reboot.
Action
If the system does not reboot automatically, reboot the system manually using the reboot command.
Execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the
supportSave command and contact your switch service provider.
PLAT-1001
Message
CP<Identifies which CP (0 or 1) is doing the reset> resetting other CP (double
reset may occur).
Message Type
LOG
Severity
INFO
Probable Cause
Indicates the other control processor (CP) is being reset. This message is typically generated by a CP
that is in the process of becoming the active CP. Note that in certain circumstances a CP may experience
a double reset and reboot twice. A CP can recover automatically even if it has rebooted twice.
Recommended
No action is required.
Action
PLAT-1002
Message
CP<Identifies which CP (0 or 1) is generating the message>: <Error message> CP
Fence 0x<CP Fence register. Contents (2 bytes) are platform-specific> 0x<CP Error
register. Contents are platform-specific> CP Error 0x<Write control flag. Contents
are platform-specific>.
Message Type
LOG
Severity
CRITICAL
Probable Cause
Indicates that the control processor (CP) cannot access the inter-integrated circuit (I2C) subsystem
because of an error condition or because of being fenced or isolated from the I2C bus.
Recommended
Reboot the CP if it does not reboot automatically. Reseat the CP if rebooting does not solve the problem.
Action
If the problem persists, replace the CP.
Fabric OS Message Reference
53-1002749-01
5