Brocade Communications Systems StoreFabric SN6500B Reference page 277

Brocade fabric os message reference v7.1.0 (53-1002749-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

CVLC-1031
Message
Primary LUN is restored from mirror LUN. LUN in read-only mode. Container: <Target
container name>, Initiator: <Initiator physical WWN>, LUN ID: <LUN ID>.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that a re-keyed primary LUN may have been restored from a mirror LUN without synchronizing.
Recommended
Perform the following steps.
Action
1. Create a new primary LUN.
2. Add the new primary LUN to its container with the
3. Using host-based migration application, copy data from the old to the new primary LUN.
CVLC-1032
Message
Secondary metadata for LUN has been restored. Container: <Target container name>,
Initiator: <Initiator physical WWN>, LUN ID: <LUN ID>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates the host I/Os to secondary metadata region.
Recommended
No action is required.
Action
CVLC-1033
Message
Rebalance completed for EE: <EE name>. Device login in progress.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that a rebalance operation was performed.
Recommended
No action is required.
Action
Fabric OS Message Reference
53-1002749-01
CVLC-1031
option.
-newLUN
5
255

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric os v7.1.0

Table of Contents