Brocade Communications Systems StoreFabric SN6500B Reference page 309

Brocade fabric os message reference v7.1.0 (53-1002749-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

EM-1037
Message
<FRU Id> is no longer faulted.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the specified power supply is no longer marked faulty; probably because its AC power
supply has been turned on.
Recommended
No action is required.
Action
EM-1042
Message
Important FRU header data for <FRU Id> is not valid.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the specified field-replaceable unit (FRU) has an incorrect number of sensors in its FRU
header-derived information. This could mean that the FRU header was corrupted or read incorrectly, or
corrupted in the object database, which contains information about all FRUs.
Recommended
Reseat the FRU. If the problem persists, replace the FRU.
Action
EM-1043
Message
Can't power <FRU Id> <state (on or off)>.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the specified field-replaceable unit (FRU) cannot be powered on or off.
Recommended
The specified FRU is not responding to the commands and should be replaced.
Action