Brocade Communications Systems StoreFabric SN6500B Reference page 882

Brocade fabric os message reference v7.1.0 (53-1002749-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

5
TRCE-1007
TRCE-1007
Message
Notification of this CP has failed. Parameters temporarily out of synch with other
CP.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the active control processor (CP) is unable to alert the standby CP of a change in trace
status. This message is only applicable to bladed switches.
Recommended
This message is often transitory. Wait a few minutes and try the command again.
Action
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
TRCE-1008
Message
Unable to load trace parameters.
Message Type
FFDC | LOG
Severity
CRITICAL
Probable Cause
Indicates that the active control processor (CP) is unable to read the stored trace parameters.
Recommended
Reboot the CP (dual-CP system) or restart the switch.
Action
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
TRCE-1009
Message
Unable to alert active CP that a dump has occurred.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the standby control processor (CP) is unable to communicate trace information to active
CP. This message is only applicable to bladed switches.
Recommended
Execute the haShow command to verify that the current CP is standby and the other CP is active.
Action
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
860
Fabric OS Message Reference
53-1002749-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric os v7.1.0

Table of Contents