Brocade Communications Systems StoreFabric SN6500B Reference page 217

Brocade fabric os message reference v7.1.0 (53-1002749-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

C3-1006
Message
S<slot number>,C<chip index>: Various non-critical hardware errors were observed:
fault1:0x<fault1_cnt>, fault2:0x<fault2_cnt> thresh1:0x<threshold_used>.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that some errors were found in hardware that may or may not impact the data traffic.
Recommended
No action is required. Usually these errors are transient.
Action
C3-1007
Message
S<slot number>,P<port number>(<blade port number>): best effort QoS will be turned
off at next port state change as it is not supported under this configuration.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that quality of service (QoS) will be turned off automatically at the next port state change
because best effort QoS is no longer supported on 4 Gbps or 8 Gbps platform long distance ports.
Recommended
No action is required.
Action
C3-1008
Message
S<slot number>,P<port number>(<blade port number>): QoS overwrites
portcfglongdistance vc_translation_link_init. ARB will be used on the link.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that quality of service (QoS) has overwritten the fill word IDLE used on the long distance links.
Arbitrated loop (ARB) will be used on the link.
Recommended
No action is required.
Action
Fabric OS Message Reference
53-1002749-01