AG-1012
Message
Sending logout (LOGO) request failed on N_Port <port number>.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that there was a failure sending an N_Port logout request from the Access Gateway to the
fabric switch.
Recommended
Check the configuration of the fabric switch connected to the Access Gateway.
Action
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
AG-1013
Message
F_Ports mapped to N_Port <port number> failed over to other N_Port(s).
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the specified N_Port is failing over to other N_Ports connected to the same fabric.
Recommended
Execute the ag --mapshow command to display updated F_Port-to-N_Port mapping.
Action
AG-1014
Message
Failing back F_Ports mapped to N_Port <port number>.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the specified N_Port is failing back F_Ports mapped to it.
Recommended
Execute the ag --mapshow command to display updated F_Port-to-N_Port mapping.
Action