Brocade Communications Systems StoreFabric SN6500B Reference page 358

Brocade fabric os message reference v7.1.0 (53-1002749-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

5
FCOE-1033
Recommended
Wait until the chassis has fully recovered before you perform any operations.
Action
FCOE-1033
Message
FIP v1 FLOGI received - VF port in use.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that a device is trying to log in to a port that already has a device logged in.
Recommended
No action is required.
Action
FCOE-1034
Message
Discarded frame received on priority <pkt_ctrlp->pri_in> for which PFC/FCoE is
disabled.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that a frame is received on the specified priority, for which priority-based flow control (PFC) or
FCoE is disabled.
Recommended
Change the CEE map assigned to the FCoE map to accommodate the PFC for the specified FCoE
Action
priority or change the FCoE priority using the fabric-map default command under the FCoE
configuration mode.
FCOE-1037
Message
Logingroup dropped for switch WWN: <switch WWN>, due to name conflict while
merging.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that same login group name exists for two different switches that have different organizationally
unique identifiers (OUIs), but the last three bytes are same.
Recommended
Create the login group for the switch World Wide Name (WWN) with another name that will not lead to a
Action
name conflict.
336
Fabric OS Message Reference
53-1002749-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric os v7.1.0

Table of Contents