AG-1036
Message
Port <port number> is connected to a non-Brocade fabric with Persistent ALPA
enabled. Check the admin guide for supported configuration.
Message Type
AUDIT | LOG
Class
CFG
Severity
WARNING
Probable Cause
Indicates that one of the ports is connected to a non-Brocade fabric.
Recommended
Refer to the Access Gateway Administrator's Guide for the supported configuration.
Action
AG-1037
Message
Trunked N_Port (<n_port>) going offline. If switchshow CLI for the connected
fabric switch port displays Persistently disabled: Area has been acquired, then
check cabling: all trunked ports should be in same ASIC Port Group.
Message Type
AUDIT | LOG
Class
CFG
Severity
INFO
Probable Cause
Indicates an incorrect cabling.
Recommended
If the switchShow command on the connected fabric switch port displays "Persistently disabled: Area
Action
has been acquired", then check cabling on the Access Gateway. All trunked ports in a single trunk must
belong to the same application-specific integrated circuit (ASIC) port group.
AG-1038
Message
Brocade 8000 ports are going to different fabrics, check N_Port (<n_port>).
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates a misconfiguration.
Recommended
Connect all ports in the port group to the same fabric.