5
C3-1009
C3-1009
Message
S<slot number>,P<port number>(<blade port number>): portcfglongdistance
vc_translation_link_init = 1 overwrites fill word IDLE. ARB will be used on the
link.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the portcfglongdistance vc_translation_link_init 1 command has overwritten the fill
word IDLE. Arbitrated loop (ARB) will be used on the link.
Recommended
No action is required.
Action
C3-1010
Message
S<slot number>,C<chip index>: Above normal hardware errors were observed:
fault1:0x<fault1_cnt>, fault2:0x<fault2_cnt> thresh2:0x<threshold_used>.
Message Type
LOG
Severity
CRITICAL
Probable Cause
Indicates that above-normal errors were observed in hardware that may or may not impact the data
traffic.
Recommended
When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
Action
slotPowerOn commands. If the problem persists, replace the blade.
C3-1011
Message
Detected a complete loss of credit on internal back-end VC: Slot <slot number>,
Port <port number>(<blade port number>) vc_no=<vc number> crd(s)lost=<Credit(s)
lost>.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that all credits have been lost on the specified virtual channel (VC) and port.
Recommended
Turn on the back-end credit recovery to reset the link and recover the lost credits. If credit recovery has
already been turned on, the link will be reset to recover the credits and no action is required.
Action