Removing the stop pin, axis 1
Use this procedure to remove the stop pin axis 1.
1
2
3
Refitting the stop pin, axis 1
Use this procedure to refit the stop pin axis 1.
1
2
Product manual - IRB 2600
3HAC035504-001 Revision: AD
Action
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot
working area.
Remove the attachment screws securing
the bracket and stop pin.
Remove the bracket and stop pin.
Action
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot
working area.
Fit the two o-rings on the stop pin.
Note
The o-rings are not used when bracket (D)
is installed.