4
5
6
7
Product manual - IRB 2600
3HAC035504-001 Revision: AD
Action
Apply load F in one direction, as shown in
the figure to the right.
Remove the load and set the dial indicator
to zero.
Apply load F in the opposite direction, as
shown in the figure to the right.
Remove the load and measure the play by
reading the dial indicator.
© Copyright 2009-2023 ABB. All rights reserved.
4.4.4 Measuring the play, axis 5
Information
xx0300000186
Values for IRB 2600 -20/1.65, -12/1.65,
-12/1.85:
•
A: Measuring tool, play
•
B: 140 mm
•
C: 85 mm
•
F: 40N
xx0300000187
Values for IRB 2600 - 20/1.65, -12/1.65,
-12/1.85:
•
A: Measuring tool, play
•
B: 140 mm
•
C: 85 mm
•
F: 40N
The maximum play allowed at the given
distance from the center of axis 5 is, for
robot version:
•
IRB 2600 -20/1.65, -12/1.65, -
12/1.85: 0.12 mm
4 Repair
Continued
275