4 Repair
4.3.1 Removing the complete cable harness
Continued
1
2
3
Continues on next page
210
Action
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot
working area.
Cut the cable strap on the lower arm.
Remove the brackets on the lower arm.
© Copyright 2009-2023 ABB. All rights reserved.
Note
See the figure in:
Location of the cable harness on
page 201
(Cable harness, lower arm)
B
A
xx0900000020
Parts:
A: Bracket, lower arm
B: Bracket, lower arm
C: Bracket, armhouse
D: Cable bracket
Product manual - IRB 2600