4 Repair
4.3.1 Removing the complete cable harness
Continued
1
2
3
Continues on next page
210
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot
working area.
Cut the cable strap on the lower arm.
Remove the brackets on the lower arm.
© Copyright 2009-2023 ABB. All rights reserved.
Note
See the figure in:
•
Location of the cable harness on
page 201
(Cable harness, lower arm)
B
A
xx0900000020
Parts:
•
A: Bracket, lower arm
•
B: Bracket, lower arm
•
C: Bracket, armhouse
•
D: Cable bracket
Product manual - IRB 2600