ABB IRB 2600ID Product Manual page 224

Table of Contents

Advertisement

4 Repair
4.3.2 Refitting the complete cable harness
Continued
Refitting the cable harness in the lower arm and armhouse
Use this procedure to refit the cable harness in the lower arm and armhouse.
1
2
3
4
Continues on next page
224
Tip
Before starting this procedure, first refit the cable harness in the frame and base.
See:
Refitting the complete cable harness on page 212
Refitting the complete cable harness on page 212
Action
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot
working area.
Secure the brackets on the lower arm.
Refit the cable straps securing the cable
harness to the lower arm.
Push the cable harness carefully into the
armhouse.
© Copyright 2009-2023 ABB. All rights reserved.
Note
B
A
xx0900000020
Parts:
A: Bracket, lower arm
B: Bracket, lower arm
C: Bracket, armhouse
D: Cable bracket
See the figure in:
Location of the cable harness on
page 213
(Cable harness, lower arm)
Product manual - IRB 2600
3HAC035504-001 Revision: AD
D
C

Hide quick links: