Inspecting additional mechanical stops
Use this procedure to inspect the additional mechanical stops on axis 1.
1
2
3
4
144
Action
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot work-
ing area.
Check the additional mechanical stops on
axis 1 for damage.
Make sure the stops are properly attached.
If any damage on stops or attachment screws
etc. is detected, the mechanical stops must
be replaced!
© Copyright 2009-2023 ABB. All rights reserved.
Note
Content is defined in section
page
452.
These procedures include references to the
tools required.
Note
See the figure in:
Location of additional mechanical
stops on page 143
Tightening torque:
82 Nm
Attachment screws:
M12x40, quality 8.8-A3F