ABB IRB 2600ID Product Manual page 242

Table of Contents

Advertisement

4 Repair
4.3.4 Replacing SMB unit
Continued
6
7
8
9
10
11
Continues on next page
242
Action
Remove the bracket by sliding it off the re-
maining three attachment screws and put
it at a 90° angle from the base.
Putting the bracket at a 90° angle facilitates
the disconnecting of cables from the
bracket.
Note
Use caution when performing this procedure
order not to damage cables or other com-
ponents!
Disconnect cable clamps.
Unscrew the attachment screws securing
the SMB unit just enough to be able to re-
move the SMB unit.
Remove the SMB unit.
Disconnect the battery cable by pressing
down the upper lip of the R1.G connector
to release the lock while pulling the connect-
or upwards.
Disconnect the remaining connectors on
the SMB unit:
R1.SMB1-2
R1.SMB3-6
R2.SMB
© Copyright 2009-2023 ABB. All rights reserved.
Note
Cable harness can stay connected to all
connectors except to the SMB unit.
xx0900000013
Parts:
A Bracket at a 90° angle
B Base
A
xx0900000035
Parts:
A Cable clamps
See the figure in:
Location of SMB unit on page 239
xx1700000993
See the figure in:
Location of SMB unit on page 239
Product manual - IRB 2600
3HAC035504-001 Revision: AD

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Irb 2600

Table of Contents