Action
Apply load F in one direction.
Remove the load and set the dial indicat-
or to zero.
Apply load F in the opposite direction,
as shown in the figure to the right.
Remove the load and measure the play
by reading the dial indicator.
© Copyright 2009-2023 ABB. All rights reserved.
4.4.5 Measuring the play, axis 6
Information
xx0300000189
Values for robot versions IRB 2600 -
20/1.65, -12/1.65, -12/1.85:
A: Measuring tool, play
B: 100 mm
C: 150 mm
F: 40N
xx0300000190
Values for robot versions IRB 2600 -
20/1.65, -12/1.65, -12/1.85:
A: Measuring tool, play
B: 100 mm
C: 150 mm
F: 40N
The maximum play allowed at the given
distance (B) from the center of axis 6 is, for
robot version:
Values for IRB 2600 -20/1.65, -
12/1.65, -12/1.85: 0.22 mm
4 Repair
Continued