ABB IRB 2600ID Product Manual page 205

Table of Contents

Advertisement

6
7
8
9
Product manual - IRB 2600
3HAC035504-001 Revision: AD
Action
Cut the cable straps securing the battery
cable.
Disconnect the battery cable.
Unscrew the thin nut securing the R1.SMB
connector on the outside of the bracket.
Tip
Use a deep well hexagon socket, width 30
mm (like the ones used for spark plugs, or
similar).
xx1200000888
Unscrew the nut for the air connection on
the inside of the bracket.
© Copyright 2009-2023 ABB. All rights reserved.
4.3.1 Removing the complete cable harness
Note
xx0900000099
Parts:
A: Cable straps (2 pcs)
D
C
xx1200000889
A Thin nut, width 30 mm
B R1.SMB
C Bracket
D Air connector
Continues on next page
4 Repair
Continued
A
B
205

Hide quick links:

Advertisement