Matrix Telecom SARVAM UMG System Manual page 535

Hide thumbs Also See for SARVAM UMG:
Table of Contents

Advertisement

If the first call has been routed through Member 1 (T1E1 Port 3), then for the next call, system will
check the status of Member 2 (T1E1 Port 4) but if the first call has been routed through Member 2
(T1E1 Port 4), then the system will check the status of Member 3 (T1E1 Port 5) to route the call.
Similarly, for the subsequent calls the system will check the next member port in the group.
Default: First Free.
Each Member can have multiple channels. For each Member,
Select the Port Number. If you do not want any more members in a group, select None as Port
Number. For example, if you want two members, Member 1 and 2 in the Group, set Port Number for
Member 3 and 4 to None.
Define the Start Channel Number. While determining the destination port, SARVAM UMG will
select this channel first for routing the calls originated on the T1E1 Port. Valid range is 1 to 30.
Default:1.
Define the Total Channels SARVAM UMG should check while routing the call. Valid range is 1 or
30. Default: 30.
Set the sequence in which SARVAM UMG should select the channel for routing the call as Channel
Selection Method. You may select:
Ascending: When you select Ascending as Channel Selection Method, SARVAM UMG will
route call to first channel. If found busy the call will be routed to the next channel.
Descending: If you select Descending, SARVAM UMG will route calls in the reverse sequence;
starting from last channel to the first.
Cyclic: If you select Cyclic, SARVAM UMG will route the first call to the first channel; if found
busy the call will be routed to the next channel. If the first call has been routed through the first
channel then the system will check the second channel for the next call but if the first call has
been routed through the second channel, the system will check the third channel to route the
call. Similarly, subsequent calls will be routed.
Click Submit to save the group.
Select Default, to set the parameters of a particular group to default.
Select Default All, to set the parameters of all the groups to default.
Similarly, you can create BRI Groups.
To create Groups of BRI Ports, click BRI- Group.