Destination Port Determination on Mobile Ports
For Mobile Port, the system supports the following methods for Destination Port Determination:
•
Fixed
•
On the basis of Destination Number
•
On the basis of Calling Party Number
To apply Destination Port Determination on the basis of Calling Party Number, you must configure the Mobile
Port - Destination Port Determination - Calling Number Based table.
To apply Destination Port Determination on the basis of Destination Number, you must configure the Mobile
Port - Destination Port Determination - Destination Number Based table.
Destination Port Determination on SIP Trunks
For SIP Trunks, the system supports the following methods for Destination Port Determination:
•
Fixed
•
On the basis of Destination Number
•
On the basis of Calling Party Number
To apply Destination Port Determination on the basis of Calling Party Number, you must configure the SIP
Trunk - Destination Port Determination - Calling Number Based table.
To apply Destination Port Determination on the basis of Destination Number, you must configure the SIP Trunk
- Destination Port Determination - Destination Number Based table.
Destination Port Determination on T1/E1 Port
For T1/E1 Port with Orientation Type - Terminal, the system allows you to configure the following destination port
determination methods by Port, Channel and MSN Number/DDI Number:
•
Fixed
•
On the basis of Destination Number
•
On the basis of Calling Party Number
For T1/E1 Port with Orientation Type - Network, the system allows you to configure the following destination port
determination methods by Port and Channel:
•
Fixed
•
On the basis of Destination Number
•
On the basis of Calling Party Number
To apply Destination Port Determination On the basis of Calling Party Number, you must configure the T1E1
Port - Destination Port Determination - Calling Number Based table.
To apply Destination Port Determination On the basis of Destination Number, you must configure the T1E1 Port
- Destination Port Determination - Destination Number Based table.
Configuring BRI Port-Calling Number Based Table
•
Click the Advanced Settings link to expand.
•
Click BRI-Calling Number Based under Destination Port Determination.
509
Matrix SARVAM UMG System Manual
Need help?
Do you have a question about the SARVAM UMG and is the answer not in the manual?