Return to ANT parameter and assign the ANT Table you configured.
•
To enable the feature Disconnect Call using Access Code on the T1E1 Port, select the Allow Call
Disconnection using Access code check box. To know more about this feature, see
Call using Access Code".
•
To customize the pulse width option and set the pulse shapes configure the Custom Pulse parameters.
SARVAM UMG generates pulse shapes which match the country standard, where it is installed. However,
if the standard pulse shape does not match, SARVAM UMG enables you to customize the pulse width to
match your exact requirements.
To use customize pulse width option and set the pulse shape in 1 to 4 phases,
•
Select the Custom Pulse Width check box.
•
In Custom Pulse Width Word 1, set the pulse width for setting pulse shape in the 1st phase. Valid
range is 0 to 127. Default: 63.
•
In Custom Pulse Width Word 2, set the pulse width for setting pulse shape in the 2nd phase.Valid
range is 001 to 127. Default: 58.
•
In Custom Pulse Width Word 3, set the pulse width for setting pulse shape in the 3rd phase. Valid
range is 001 to 127. Default: 76.
•
In Custom Pulse Width Word 4, set the pulse width for setting pulse shape in the 4th phase. Valid
range is 001 to 127. Default: 0.
439
"Disconnecting a
Matrix SARVAM UMG System Manual