Set the duration of the Inter Digit Wait Timer. This is the duration for which you want the system to
wait while receiving the digits dialed by the caller to consider it as End of Dialing. You may change this
timer, if required. Valid range is 01 to 99 seconds. Default: 05 seconds.
•
As End of Dialing Digit, select whether the system should consider # or * as termination digit to detect
end of dialing. Default: #
•
In Minimum number of digits that can be dialed by the caller, select the minimum number of digits
to be dialed by the user for the system to consider it as a valid number. Valid range is 01 to 24 digits.
Default: 2 digits.
•
In Maximum number of digits that can be dialed by the caller, define the maximum number of digits
to be dialed by the user for the system to consider it as End of Dialing. Valid range is 01 to 24 digits.
Default: 24 digits.
Destination Port Determination
For the port/channel number, select the Destination Port for routing calls from the following options:
•
Fixed
•
On the basis of Destination Number
•
On the basis of Calling Party Number
Default: Fixed.
Read the description and follow the instructions for each of these destination port selection methods given
below.
If the destination number to be dialed out is an IP Address, SARVAM UMG will not check the Destination
Port Determination Method. Instead, it will route the call using the SIP Trunk / Group programmed for IP
Dialing. (To know more, see the feature description
Fixed
In this method, calls received on the BRI Port are routed to a Fixed Destination Port, irrespective of the number
dialed on the BRI Port.
To apply this method, do the following:
•
In Select Destination Port for routing calls, select Fixed option.
Matrix SARVAM UMG System Manual
"IP
Dialing").