In Custom Pulse Width Word 2, set the pulse width for setting pulse shape in the 2nd phase.Valid
range is 001 to 127. Default: 58.
In Custom Pulse Width Word 3, set the pulse width for setting pulse shape in the 3rd phase. Valid
range is 001 to 127. Default: 76.
In Custom Pulse Width Word 4, set the pulse width for setting pulse shape in the 4th phase. Valid
range is 001 to 127. Default: 0.
PRI Settings
If you have selected PRI as Signaling Type, configure the PRI parameters.
Click PRI Settings to expand.
Set the duration of the Overlap Receiving Timer. This timer is relevant while receiving the called party
number information in overlap receiving mode. Valid range is 01 to 99 seconds. Default: 5 seconds.
Select the required option for sending the Caller-Type of Numbering Plan (TON) — Unknown,
International, National, Network Specific, Subscriber, Abbreviated or Reserved. Default: Unknown.
Select the required option for sending the Caller-Numbering Plan Identification (NPI) — Unknown,
ISDN Numbering, Data Numbering, Telex Numbering, National Numbering, Private or Reserved.
Default: ISDN Numbering.
Select the required option for sending the Called-Type of Numbering Plan (TON) — Unknown,
International, National, Network Specific, Subscriber, Abbreviated or Reserved. Default: Unknown.