RBS parameters window opens.
Line Signaling Variants
•
Select the Line Signaling Variant. You can select — FXS Loop Start, FXO Loop Start, FXS Ground Start,
FXO Ground Start, E&M Immediate Dial/Start, E&M Wink Start or E&M Wink Start FGD. Default: E&M
Wink Start FGD.
•
Set the duration of the Wink Timer. This signifies the momentary Off-Hook condition to acknowledge end
of an outgoing call. Valid range is 0001 to 9999 msec. Default: 160 msec.
•
Set the duration of the Wink Wait Timer. This signifies the maximum time the system should wait before
sending a wink start signal after an incoming seizure is detected. Valid range is 0001 to 9999 msec.
Default: 30 msec.
Ensure that this timer is greater than the Wink Wait Timer of the other end.
•
Set the duration of the Wait Wink Timer. This signifies the time for which SARVAM UMG will wait for
receiving the DNIS after sending the outgoing seizure signal. Valid range is 0001 to 9999 msec. Default:
5000 msec.
Make sure that this timer is greater than the Wait Wink Timer of the other end.
389
Matrix SARVAM UMG System Manual