Overview of Alarms
NCK alarms
10207
Channel %1 error when selecting or deselecting the digitize function
Parameters:
%1 = Channel number
Definitions:
An error has occurred on activating/deactivating the digitizing module; e.g. not in channel ready state,
already activated, etc.
Reaction:
Alarm display.
Remedy:
Press RESET.
Program
Clear alarm with the Delete key or NC START.
Continuation:
10208
Channel %1 continue program with NC start
Parameters:
%1 = Channel number
Definitions:
After block search with calculation, the control is in the desired state. The program can now be started
with NC Start or the state can be changed for the time being with overstore/jog.
Reaction:
Interpreter stop
Alarm display.
NC Stop on alarm.
Remedy:
Press NC Start.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
10209
Channel %1 internal NC stop after block search
Parameters:
%1 = Channel number
Definitions:
Internal alarm which only initiates the alarm response NC Stop.
The alarm is output in the following situations:
- If $MN_SEARCH_RUN_MODE bit 0 ==1 and the last action block is loaded in the main run after
block search. Alarm 10208 is then activated as a function of the VDI signal PLC -> NCK channel
DBB1.6.
- Search alarm 10208 has been suppressed by the PI service _N_FINDBL (third decade of the
parameter supplied with "2"). Alarm 10209 is set as a function of whether or not a search ASUB has
been configured ( $MN_SEARCHRUN_MODE bit 1) with the end of the search ASUB or the loading
of the last action block in the main run.
Reaction:
Interpreter stop
NC Stop on alarm.
Remedy:
NC-Start
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
10220
[up to SW 3.x only] Channel %1 active
Parameters:
%1 = Channel number
Definitions:
The internal command "delete NC blocks prepared by preprocessor and reorganize (REORG)" has
been requested for this channel. It is initiated, e.g. as a result of an overstore, but cannot be executed
in a running channel.
Reaction:
Alarm display.
Remedy:
Stop the channel (NC Stop) and repeat the action.
Program
Clear alarm with the Delete key or NC START.
Continuation:
2-98