Siemens SINUMERIK 840Di Diagnostic Manual page 540

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

Overview of Alarms
NCK alarms
61331
Channel %1 Block %2: Angle too large, change measuring axis
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Parameter _STA is too large of the specified metering shaft. Alarm is triggered: CYCLE998.
Remedy:
Select another metering axis.
61332
Channel %1 Block %2: Modify tool tip position
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The tool tip is below the measuring probe surface (e.g. for a ring gauge or cube). Alarm is triggered:
CYCLE971, CYLCE972, CYCLE982, E_MT_CAL, E_MT_LEN, E_MT_RAD.
Remedy:
Place the tool above the measuring probe surface.
61333
Channel %1 Block %2: Check calibration facility number
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Parameter _CALNUM is too large. Alarm is triggered: CYCLE973.
Remedy:
Reduce _CALNUM to a permissible value or increase maximum value _CVAL[2] in GUD6.
61334
Channel %1 Block %2: Check safety area
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Parameter _SZA, _SZO too large or too small. Alarm is triggered: CYCLE977.
Remedy:
Check parameter _SZA, _SZO.
61336
Channel %1 Block %2: Geometry axes do not exist
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
No geometry axes configured. Alarm can be triggered by following measuring cycles: all measuring
cycles.
Remedy:
Machine data in MD 20060 must be changed.
61337
Channel %1 Block %2: Check measuring input
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61338
Channel %1 Block %2: Positioning speed equal to zero
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
For some measuring versions, for example measuring spigots, in addition to the actual measuring
paths, intermediate paths are generated that are traversed with a specified feed. The values for the
feed are specified in parameters _SPEED[1] and _SPEED[2] in GUD6.
Alarm triggered by following measuring cycles: all measuring cycles.
Remedy:
Check parameter _SPEED[1], _SPEED[2] in GUD6.
2-540
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
11/2006

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents